RUBBERALL® UNCURED FLASHING PATCH
Description
RUBBERALL® Uncured Flashing Patch (11 5/8" x 12") is a self-curing EPDM Rubber.
Storage
- Store in original unopened cartons at temperatures between 60°F and 80°F until ready for use.
- During hot weather, do not expose to sunlight/elevated temperatures until use.
- Rotate your stock to insure stored material will not go beyond the shelf life of twelve months from listed date of manufacture.
Shelf Life
- A shelf life of twelve months from listed date of manufacture can be expected when stored at temperatures between 60°F and 80°F.
- Shelf life will be shortened when exposed to elevated temperatures.
Technical Specifications
Property |
Test Method |
Specifications |
Specific Gravity |
ASTM-D-297 |
1.15 +/- .05- |
Elongation |
ASTM-D-412 |
300% minimum |
Brittleness Temperature |
ASTM-D-746 |
-49°F (-45°C) |
Tensile Strength |
ASTM-D-412 |
1305 psi minimum |
Tear Resistance |
ASTM-D-624 |
150 obs/in minimum |
Heat Aging
28 Days @ 240°F |
ASTM-D-573 |
Tensile minimum
1205 psi (tensile)
200% min. (elongation) |
Ozone Resistance
7 days/100pphm@
100°F with 50% extension |
ASTM-D-1149 |
No Cracks |
Water Resistance
change in weight after
immersion 7 days @
150°F, % |
ASTM-D471 |
+8, -2 |
Weight |
|
.35 lb/ft2 |
Physical Characteristics
- A self-curing EPDM Rubber.
- Adaptable to irregular shapes and surfaces.
- Superior weathering characteristics.
Method of Application
- Substrates must be clean, dry, smooth, free of sharp edges, fins, loose or foreign materials, oil grease, and other materials that may damage the Uncured Flashing.
- All roughened surfaces which could damage the Uncured Flashing Patch should be repaired as specified to offer a smooth substrate.
- All surface voids greater than 1/4" wide shall be properly filled with an acceptable fill material.
- Install Uncured Flashing Patch in accordance with current RUBBERALL® Specifications, Details and Workmanship requirements.
Precautions
- Keep away from fire and ignition sources during storage and installation.
- Use of heat guns during cold weather will improve workability of Uncured Flashing Patch, but a wide nozzle should be used and care should be taken not to localize heat, as a hole in the flashing can result.
return to top of page |
|
|