Water Tight Technologies

  RUBBERALL® Family of Products
  RUBBERALL® Membrane Qualities
 
  Warranty
  Installation Manual
  Installation Video Guide
 
see Printer-Friendly Version

RUBBERALL® UNCURED FLASHING PATCH

Description
RUBBERALL® Uncured Flashing Patch (11 5/8" x 12") is a self-curing EPDM Rubber.

Uncured Flashing PatchStorage

  1. Store in original unopened cartons at temperatures between 60°F and 80°F until ready for use.
  2. During hot weather, do not expose to sunlight/elevated temperatures until use.
  3. Rotate your stock to insure stored material will not go beyond the shelf life of twelve months from listed date of manufacture.

Shelf Life

  1. A shelf life of twelve months from listed date of manufacture can be expected when stored at temperatures between 60°F and 80°F.
  2. Shelf life will be shortened when exposed to elevated temperatures.

Technical Specifications

Property

Test Method

Specifications

Specific Gravity

ASTM-D-297

1.15 +/- .05-

Elongation

ASTM-D-412

300% minimum

Brittleness Temperature

ASTM-D-746

-49°F (-45°C)

Tensile Strength

ASTM-D-412

1305 psi minimum

Tear Resistance

ASTM-D-624

150 obs/in minimum

Heat Aging
28 Days @ 240°F

ASTM-D-573

Tensile minimum
1205 psi (tensile)
200% min. (elongation)

Ozone Resistance
7 days/100pphm@
100°F with 50% extension

ASTM-D-1149

No Cracks

Water Resistance
change in weight after
immersion 7 days @
150°F, %

ASTM-D471

+8, -2

Weight

 

.35 lb/ft2

Physical Characteristics

  1. A self-curing EPDM Rubber.
  2. Adaptable to irregular shapes and surfaces.
  3. Superior weathering characteristics.

Method of Application

  1. Substrates must be clean, dry, smooth, free of sharp edges, fins, loose or foreign materials, oil grease, and other materials that may damage the Uncured Flashing.
  2. All roughened surfaces which could damage the Uncured Flashing Patch should be repaired as specified to offer a smooth substrate.
  3. All surface voids greater than 1/4" wide shall be properly filled with an acceptable fill material.
  4. Install Uncured Flashing Patch in accordance with current RUBBERALL® Specifications, Details and Workmanship requirements.

Precautions

  1. Keep away from fire and ignition sources during storage and installation.
  2. Use of heat guns during cold weather will improve workability of Uncured Flashing Patch, but a wide nozzle should be used and care should be taken not to localize heat, as a hole in the flashing can result.

return to top of page

 
 
Home About RUBBERALL Roofing Products Water Garden Products Contact Us About BRITE-N-EZ BRITE-N-EZ Roofing Products Roof Coatings Site Map